Durability + Design
Follow us on Twitter Follow us on LinkedIn Like us on Facebook Follow us on Instagram Visit the TPC Store
Search the site

 

D+D News

Main News Page


Retrofit Proposed for Sinking Millennium Tower

Thursday, April 19, 2018

More items for Maintenance + Renovation

Comment | More

The saga of the sinking Millennium Tower continues, but a fix may be in sight: drilling holes down to bedrock in order to stabilize one side of the tower while letting the other side sink down, allowing the building to level itself out.

With the work estimated to cost anywhere from $200 million to $500 million, this work could easily equal the original cost of the construction of the tower—$350 million.

Fixing the Sinking Tower

The structure’s sinking and settling led to gaps forming in the walls, which kicked off an investigation in 2016, after several residents had complained of “unexplained odors permeating their luxury units.”  

In January, an exploratory drilling project evaluated the feasibility of the micro pile fix, which took 10 weeks.

According to the San Francisco Chronicle, the 58-story tower sits on a 10-foot-thick mat foundation, held in position by 950 reinforced concrete piles sunk 60 to 90 feet into clay and mud, which do not reach the bedrock. To fix the leaning issue, engineers are suggesting boring 275 to 300 steel and concrete “micro piles” down to bedrock, only on one side of the building at a time, starting with the west side.

Once the structure is stabilized, the east side would be allowed to sink until the building straightens itself. Then, micro piles would also be driven into that side, preventing the structure from sinking any further.

Hydrogen Iodide, public domain, via Wikimedia Commons

The saga of the sinking Millennium Tower continues, but a fix may be in sight: drilling holes down to bedrock in order to stabilize one side of the tower while letting the other sink down to the point where the building levels itself out.

Repairs are slated to take two to five years. Currently, the building’s contractor and engineers are seeking the needed permits to complete the work.

But others are not so sure of the idea: attorney Frank Pitre, representing 85 Millennium condo owners separate the homeowners’ association, said that he thought this was not a fix. “At best, this is going to arrest further tilting of the building.”

David Casselman, a Los Angeles lawyer representing 265 owners separately from Pitre, is suing the Transbay Joint Powers Authority, which is currently wrapping up construction on the nearby Transbay Transit Center. Casselman claims that he has evidence that the authority—composed of the California High Speed Rail Authority, San Francisco, AC Transit, the Peninsula Corridor Joint Powers Board and Caltrans—ignored its obligation to prevent the structure from sinking when excavation work began on the Transit Center.

Test samples of the soil and bedrock will be taken in the next several days. Before repairs can begin, however, parties must come up with a comprehensive agreement to both fund the work and settle the claims from condo owners.

To date, the tower has sunk 17 inches and tilted 14 inches to the west and 6 inches to the north.

   

Tagged categories: Architecture; Condominiums/High-Rise Residential; Government; Health and safety

Comment from john lienert, (4/19/2018, 8:03 AM)

hahahahaha


Comment Join the Conversation:

Sign in to our community to add your comments.

Advertisements
 
Novatek Corporation
 
Novatek Portable Air Filtration Systems
 
Air Scrubbers/Negative Air machines for restoration, abatement, dust & odor control, hazardous contaminant removal from job sites to clean rooms and hospitals. Portable, affordable!
 

 
Keim Mineral Coatings
 
Mineral Silicate Paints + Stains Fuse to Concrete
 
• Forms permanent chemical bonds
• Becomes part of the concrete
• Will never peel
• Looks completely natural
 

 
Shield Industries, Inc
 
FireGuard® E-84 Intumescent Coating - Shield Industries, Inc
 
Trust the certified protection of the industry’s most innovative intumescent coating FireGuard® E-84 to provide you with the 1 and 2 hour fire ratings you need.
 

 
 
 

Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@durabilityanddesign.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 

© Copyright 2012-2018, Technology Publishing Co., All rights reserved