Cladding in Fatal London Tower Fire ID'd

Tuesday, June 20, 2017

More items for Building Envelope

Comment | More

A deeper look into the Glenfell Tower’s 2016 renovation has unveiled that Reynobond PE (polyethylene) panels were used instead of Reynobond (FR) fire-resistant ones in the high-rise.

The tower went up in flames early last Wednesday (June 14) and 79 people are believed to have died in the blaze, though officials note the count could still change. Soon after the structure ignited, officials were quick to suspect the building’s exterior as the reason for why the fire was so devastating.

The Cladding

Manufacturer Omnis Exteriors confirmed that they supplied the Arconic Architectural Product to Harley Facades—the subcontractor in charge of the cladding work.

Arconic

Manufacturer Omnis Exteriors confirmed that they supplied the Arconic Architectural Product to Harley Facades—the subcontractor in charge of the cladding work.

The aluminum-composite panels with a core of flammable, plastic polyethylene were reportedly 2 pounds ($2.55) cheaper per square meter than the fire-resistant panels.

General contractor Rydon Maintenance said in a statement last week that the renovation was up to code.

“We are shocked to hear of the devastating fire at Grenfell Tower and our immediate thoughts are with those that have been affected by the incident, their families, relatives and friends,” the statement read. “Rydon completed a refurbishment of the building in the summer of 2016 for KCTMO on behalf of the Council, which met all required building control, fire regulation and health and safety standards.”

However, Chancellor Philip Hammond is claiming that cladding is illegal in the United Kingdom.

"My understanding is the cladding in question, this flammable cladding which is banned in Europe and the U.S., is also banned here,” Hammond said. "So, there are two separate questions. One: are our regulations correct, do they permit the right kind of materials and ban the wrong kind of materials? The second question is: were they correctly complied with? That will be a subject that the inquiry will look at. It will also be a subject that the criminal investigation will be looking at."

That statement was soon challenged by John Cowley, the managing director of CRP Architectural Façades, which is owned by Omnis and fabricated the panels.

"Reynobond PE is not banned in the U.K. Current building regulations allow its use in both low-rise and high-rise structures," said Cowley in a statement. "The key question now is whether the overall design of the building's complete exterior was properly tested and subsequently signed off by the relevant authorities—including the fire officer, building compliance officer and architect—before commencement of the project.”

Legal Matters

Plastic-filled cladding such as the Reynobond PE is also banned from high-rise use in Germany, which restricts the product to buildings less than 72 feet high—or about the height that firefighters can reach with extended ladders from the ground. The United States restricts the use in buildings above 49 feet.

Berlin’s fire chief, Wilfried Gräfling, said the London fire made it clear that fire regulations should be tightened further with only mineral materials used in cladding panels.

“We will try to persuade lawmakers that flammable material should no longer be allowed to be used as an insulant,” he said. “Only mineral material that can’t burn, ensuring that it’s no longer possible for a fire to spread via the cladding.”

The Guardian reports that the Fire Protection Association has been pushing for stricter requirements for the use of fire-retardant material, saying that those officials have “lobbied long and hard” but nothing had happened.

The police have launched a criminal inquiry into the fire, along with the U.K.’s public inquiry and an emergency review of 4,000 similar buildings.

   

Tagged categories: Aluminum; Cladding; Condominiums/High-Rise Residential; Fire; Fireproofing; Polyethylene

Comment from Jonathan Ochshorn, (6/20/2017, 9:42 AM)

"The United States restricts the use [of plastic filled cladding panels] in buildings above 49 feet." My reading of the 2015 IBC is that all buildings are subject to NFPA 285 (which limits flame propagation horizontally and vertically) with exceptions only for certain 1-story buildings; I see no 49-foot exception (there appears to be a 40-foot exception for fiber-reinforced polymers only). But I've seen articles claiming an under-40-foot-high exception from NFPA 285 (http://www.fireengineering.com/content/dam/fe/online-articles/documents/2015/Valiulis.pdf) so I'd like to see some comments that settle this question.


Comment from Jonathan Ochshorn, (6/20/2017, 9:54 AM)

Per comment above, I now see that the U.S. does have a 40-foot-high (not 49-foot) exception for compliance with NFPA 285 per Chapter 14 - Exterior Walls.


Comment Join the Conversation:

Sign in to our community to add your comments.

Advertisements
 
LATICRETE International, Inc.
 
SPARTACOTE Flex PURE Clinical Plus Coatings
 
Equipped with antimicrobial technology, fast-cure systems and high-traction features. Ideal for demanding environments. Customizable colors and textures.
 

 
RCI, Inc.
 
RCI Building Envelope Technology Symposium
 
November 13-14, 2017 | Orlando, Florida | Learn valuable design and repair insights from 20 leading design experts. RCI, Inc. is an AIA LU provider. Learn more.
 

 
Greenbuild
 
Greenbuild and ABX Together in Boston
 
Come to Boston and enjoy a 2 in 1 event! Greenbuild and ABX come together with over 700 exhibitors from the construction and design industry - register today!
 

 
Atlas Material Testing Technology
 
Helping You Put Your Products To The Test
 
  • Outdoor Accelerated Weathering
  • Laboratory Testing Services
  • Accelerated Weathering Instruments

  • www.atlas-mts.com
    atlas.info@ametek.com
 

 
World of Concrete
 
WOC 2018 – Las Vegas, NV
 
Visit the WOC website for more details about the World of Concrete 2018: January 23-26; Seminars 22-26 at the Las Vegas Convention Center in Las Vegas, NV, USA.
 

 
PPG Paints
 
NEW FORMULA! PPG PAINTS™ SEAL GRIP® PRIMER
 
PPG Paints Seal Grip Interior/Exterior Acrylic Universal Primer/Sealer has been reformulated to meet your toughest interior and exterior primer requirements.
VIEW PRODUCT
 

 
A&I Coatings
 
Vitreflon – the hallmark of colour stable protective coatings
 
Vitreflon two pack fluoropolymer coatings display unsurpassed colour and gloss retention making Vitreflon the coating of choice for high value infrastructure and architecture. Contact us today to find out how Vitreflon can outperform on your next project. Vitreflon distributorships available.
 

 
 
 

Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@durabilityanddesign.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 

© Copyright 2012-2017, Technology Publishing Co., All rights reserved